Milestone: Smoke & Fire Detection Plugin Configuration

This page provides instructions for configuring the main settings of the Smoke & Fire Detection Plugin in the XProtect Management Client.

Introduction

Open the XProtect Management Client application and sign in by performing the following steps in the login dialog:

  1. Specify the hostname or the IP address of the Management Server in the Computer field
  2. Select the desired authentication method
  3. Enter the username and password
  4. Click the Sign In button

Plugin Configuration

To configure the Smoke & Fire Detection plugin, follow these steps:

  1. Open the Tools tab in the menu bar and select Options from the drop-down menu (or press Ctrl + O)
  2. Navigate to the SmokeFireDetectionPlugin tab
  3. Set parameters as required:
    • In the Options block:
      • Enter the IncoreSoft VEZHA Middleware Core server address in the HostText field. If installed on the current PC, use "localhost".
      • Specify the port (2001 by default).
      • Enter the Milestone Management Server address in the Milestone Server field. If installed on the current PC, use "localhost".
      • Select the desired interface language.
    • In the Authorization block:
      • Specify the VEZHA login and password.
      • Click the Sign In button to connect to the VEZHA system.
      • Specify the ONVIF login and password.
  4. Click the Ok button in the Options pop-up window to save the settings
The ONVIF login and password refer to the Milestone basic user previously added to the Open Network Bridge Manager.

Analytics Configuration

To proceed with the Smoke & Fire Detection analytics configuration:

  1. Open the Incoresoft Smoke and Fire Detection section and select the Smoke and Fire Detection Analytics item
  2. View the list of analytics

Add Analytics

To add new analytics, right-click Smoke and Fire Detection Analytics and select Add New from the drop-down menu (or press Ctrl + N):

The Add Smoke and Fire Detection pop-up window opens.

The first settings block provides the ability to add a Milestone video source:

  1. Choose the desired video source from Milestone:
    • Click the Choose Camera button
    • Select the desired video source in the opened window
    • Click the Ok button
  2. Select the desired connection method:
    • For the Add Video Stream with Open Bridge (ONVIF) method:
      • Enter the Open Bridge login
      • Enter the Open Bridge password
    • For the Add Video Stream with Device method:
      • Specify the path to the associated video stream
      • If required, select the Authorization checkbox and enter the required login and password to access the video stream
  3. Click the Next button to proceed with the analytics configuration

The second settings block provides the ability to:

  1. Configure recognition options: Specify the desired number of frames per second for analytics
  2. Set hardware parameters:
    • Choose the CPU or GPU hardware acceleration
    • Select the hardware decoder from the drop-down list:
      • CPU
      • Intel
      • NVIDIA
  3. Customize the zone options:
    • Set the detection zone:
      • Left-click the frame in the desired place to set the first zone point
      • Move the mouse across the frame and left-click again to set another zone point
      • Repeat until all zone borders are set
      • Right-click the frame to complete the detection zone and create a related new rule
      • Hold and drag the area inside the zone to move the whole zone
    • Set the notification parameters:
      • Set the required time frame for territory scanning
      • Enter the notification alert delay in seconds
      • Click the Delete icon to delete the rule with the related detection zone
  4. Click the Finish button to save the new analytics
  5. Wait once the analytics setup process is complete and click the Ok button to close the Add Smoke and Fire Detection pop-up window
  • The detection zone is based on at least 3 points.
  • The Notification Alert Delay, sec parameter is responsible for the frequency with which the system sends notifications. The possible range is from 1 to 300 sec.

Edit Analytics

Once the new analytics is created, it appears in the main list of analytics. Click the desired analytics name to view its information:

  1. In the Info tab:
    • Select the Enabled checkbox to start the analytics
    • Deselect the Enabled checkbox to stop the analytics
    • Edit the analytics name
    • Provide a brief description of the analytics
    • Select the Send as Analytics Event checkbox and choose the desired event from the drop-down list to send all event notifications to the Milestone Event Server
  2. In the Recognition Options tab edit the analytics parameters as required:
    • Configure recognition options
    • Set hardware parameters
    • Customize the zone options
  3. Press Ctrl + S to apply changes
  • When the Send Events to the Milestone Event Server checkbox is selected, event notifications are directly sent to the Event Server without requiring additional notification configuration in the VEZHA system through the Event Manager.
  • The parameter configuration process in the Recognition Options tab is similar to the one described in the Add Analytics section of this document, except for the video source connection.

Delete Analytics

To delete the analytics:

  1. Right-click the analytics name
  2. Select Delete from the drop-down menu (or press Del)
  3. Confirm the intention